Basic devices in the power range 250 ... 400 kW
DC supply 400/500 V devices

5.5
5.5.5

l

5.5−8

EDSVF9383V EN 7.1−04/2012

5.5.5

DC supply 400/500 V devices

(

Stop!

The user is responsible for sufficient strain relief!

ƒ For compliance with EMC requirements, Lenze recommends to use

shielded DC−bus cables.

ƒ Shield clamps are not included in the scope of supply.

ƒ Both, the master and the slave must be supplied!

BR2

BR2

BR1

BR1

+U

G

+U

G

-U

G

-U

G

PE

PE

U

U

V

V

W

W

L1

L1

101

101

102

102

103

103

10

4

10

4

L2

L2

L3

L3

PE

PE

40 mm

40 mm

PE

15-20

Nm

M6

133-176 l

b-in

PE

15-20

Nm

M6

133-176 l

b-in

+U

G

+U

G

-U

G

-U

G

25-30

Nm

25-30

Nm

M8

M8

221-26

4 lb-in

221-26

4 lb-in

max.

300 mm

max.

300 mm

3

3

2

2

0

1

9300VEC083

Fig. 5.5−9

Connection example to +U

G

and −U

G

BR1, BR2

Brake resistors can only be operated with variants V270 and V300

0

Master terminals

1

Slave terminals

2

Connect the DC−bus cable shield to the conductive control cabinet
mounting plate with a contact surface as large as possible by using
the shield clamps.

3

Conductive surface

Ensure to have the poles right!

5.5.6

Fan connection 400/500 V devices

)

Note!

Connect the fan to the master and the slave.

Lay a bridge between the terminals when a controller is operated on a mains.

AC 340 ... 440 V

AC 440 ... 577 V

(when being delivered)

L1

L2

101

102

103

104

101

102

103

104

L1

L2

9300vec044

9300vec045

Fan connection when
controller is supplied with
mains voltage