Configuration

Code table

8

8.5

l

8.5−2

EDSVF9383V EN 4.0−03/2006

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0005

s

Signal CFG

Selection of the basic
configuration

1000 0

Common

Modified basic
configuration

The first two digits indicate the
predefined basic function, e. g.:

l

01xxx: Speed control

The third digit indicates additional
functions:

l

xx0xx: No additional function

l

xx1xx: Brake control

l

xx2xx: Setpoint selection via
motor potentiometer

l

xx3xx: PID controller

l

xx4xx: Mains failure control

l

xx5xx: Setpoint selection via
master frequency

l

xx6xx: Gearbox factor − analog
trimming

l

xx7xx: Gearbox factor − digital
trimming

l

xx8xx: Master frequency ramp
function generator

The fourth digit indicates the
predefined voltage source for the
control terminals:

l

xxx0x: External supply voltage

l

xxx1x: Internal supply voltage

The fifth digit indicates the
predefined device control

l

xxxx0: Terminal control

l

xxxx1: RS232, RS485 or optical
fibre

l

xxxx3: INTERBUS or
PROFIBUS−DP

l

xxxx5: System bus (CAN)

100

CFG: emty

All internal
connections are
removed

1000

Speed mode

Speed control

2000

Step mode

Step control

3000

Lead screw

Traversing control

4000

Torque mode

Torque control

5000

DF master

Digital frequency
master

6000

DF slv bus

Master frequency
slave (bar)

7000

DF slv cas

Digital frequency
slave (cascade)

8000

Dancer ctrl e

Dancer position
control with
external diameter
measurement

9000

Dancer ctrl i

Dancer position
control with
internal diameter
measurement

C0006

s

Op mode

5

Selection of the operating mode
for the motor control

1

vector ctrl

Vector control
without or with
speed feedback

In case of the first selection enter
the motor data and identify them
with C0148.

^ 6.8−8

5

V / f

V/f characteristic
control

Commissioning without
identification of the motor data is
possible

l

Advantage of identification
with C0148: Improved smooth
running at low speeds

^ 6.8−4

C0009 LECOM address

1

1

{1}

99 LECOM controller address

l

Bus device number when
operated via interface

l

10, 20 ... 90 reserved for
broadcast to device groups
with RS232, RS485, optical
fibre