Configuration – Lenze EVF9383 User Manual

Page 273

Advertising
background image

Configuration

Function blocks

Internal motor control with vector control (MCTRL2)

8

8.2

8.2.7

l

8.2−57

EDSVF9383V EN 7.1−04/2012

When the speed falls below a settable speed setpoint threshold, the function
"DC injection braking" is activated.

)

Note!

Automatic DC−injection braking has priority over quick stop.

Special features of vector control with feedback

ƒ If the DC braking current (C0036)

£ than the motor magnetising current,

the motor magnetising current is injected.

ƒ If the DC braking current (C0036)

> than the motor magnetising current,

the DC braking current is injected.

Setting

Selection

Code

Description

DC braking current

C0036

DC braking current with which the motor is braked

Speed setpoint threshold

C0019

If the values fall below the threshold, DC−injection
braking is released

Hold time

C0107

Duration of DC−injection braking. After the hold time,
pulse inhibit is set.

(

Stop!

An excessive DC braking current and braking time can thermally
overload the motor. Special care must be taken when using
self−ventilated motors.

Automatic DC injection
braking

Advertising
This manual is related to the following products: