Configuration, Code table – Lenze EVF9383 User Manual

Page 310

Advertising
background image

Configuration

Code table

8

8.5

l

8.5−22

EDSVF9383V EN 4.0−03/2006

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0325 Vp2 adapt

1.0

0.1

{0.1 }

500.0 Function block PTCTRL1

l

Adaptation of gain V

p2

See System
Manual
(extension)

C0326 Vp3 adapt

1.0

0.1

{0.1 }

500.0 Function block PTCTRL1

l

Adaptation of gain V

p3

C0327 Set2 adapt

100.0

0

0.00

{0.01 %}

100.00 Function block PTCTRL1

l

Adaptation of setpoint speed
threshold n

set2

l

Condition: C0327 > C0328

C0328 Set1 adapt

0.00

0.00

{0.01 %}

100.00 Function block PTCTRL1

l

Adaptation of setpoint speed
threshold n

set1

l

Condition: C0328 < C0327

C0329 Adapt on/off

0

0

No adaptation of the process controller Function block PTCTRL1

l

Adaptation On/Off

1

External adaptation via input

2

Adaptation via setpoint

3

Adaptation via control difference

C0332 PCTRL Tir

0

0

{1 s}

10000 Acceleration time T

ir

, function

block PCTRL1

l

The acceleration time refers to
a setpoint change of 0 ... 100 %

See System
Manual
(extension)

C0333 PCTRL1 Tif

0

0

{1 s}

10000 Deceleration time T

if

, function

block PCTRL1

l

The deceleration time refers to
a setpoint change of 100 % ... 0

C0336 DIS: act Up

0.0

{0.1 }

500.0 Current gain V

p

, function block

PCTRL1

l

Read only

See System
Manual
(extension)

C0337 Bi/unipolar

0

Sphere of action, function block
PCTRL1

0

Bipolar

l

Output value is limited to
−100 ... 100 %

1

Unipolar

l

Output value is limited to
0 ... 100 %

C0338 ARIT1 funct

1

0

OUT = IN1

Selection of function, function
block ARIT1

See System
Manual
(extension)

1

OUT = IN1 + IN2

2

OUT = IN1 − IN2

3

OUT = IN1 * IN2

4

OUT = IN1 / IN2

5

OUT = IN1 / (100 − IN2)

C0339

s

^ Selection list 1

Configuration of analog input
signals, function block ARIT1

1 CFG: IN

1000 FIXED0%

ARIT1−IN1

2 CFG: IN

1000 FIXED0%

ARIT1−IN2

C0340

−199.99

{0.01 %}

199.99 Function block ARIT1

l

Display of the signals linked in
C0339

1 DIS: IN

ARIT1−IN1

2 DIS: IN

ARIT1−IN2

C0350 CAN address

1

1

{1}

63 System bus node address

l

Change is effective after ˜Reset
node˜ command

C0351 CAN baudrate

0

0

500 kbit/s

System bus baud rate

l

Change is effective after ˜Reset
node˜ command

1

250 kbit/s

2

125 kbit/s

3

50 kbit/s

4

1000 kbit/s

Advertising
This manual is related to the following products: