1 general data and operating conditions, General data and operating conditions, Technical data – Lenze EVF9383 User Manual

Page 33

Advertising
background image

Technical data

General data and operating conditions

3

3.1

l

3.1−1

EDSVF9383V EN 4.0−11/2007

3.1

General data and operating conditions

Conformity and approval

Conformity

CE

2006/95/EC

Low−Voltage Directive

Protection of persons and equipment

Type of protection

EN 60529

IP20

NEMA 250

Protection against accidental contact according to
type 1

Earth leakage current IEC/EN 61800−5−1 > 3.5 mA

Observe regulations and
safety instructions!

Insulation of control
circuits

IEC/EN 61800−5−1 Safe mains isolation by double (reinforced)

insulation for the terminals X1 and X5.
Basic insulation (single isolating distance) for the
terminals X3, X4, X6, X8, X9, X10 and X11.

Insulation resistance

EN 61800−5−1

< 2000 m site altitude: Overvoltage category III

> 2000 m site altitude: Overvoltage category II

Protective measures

Against short circuit, earth fault (earth−fault
protected during operation, limited earth−fault
protection during mains power−up), overvoltage,
motor stalling, motor overtemperature (input for
PTC or thermal contact)

EMC

Noise emission

EN 61800−3

Cable−guided, up to 50 m motor cable length with
RFI filter: Category C2.

Radiation, with RFI filter and installation in control
cabinet: Category C2

Interference
immunity

IEC/EN 61800−3

Category C3

General data