2 diagnostics, Diagnostics, Troubleshooting and fault elimination – Lenze EVF9383 User Manual

Page 386

Advertising
background image

Troubleshooting and fault elimination

Display of operating data, diagnostics
Diagnostics

9

9.1
9.1.2

l

9.1−2

EDSVF9383V EN 7.1−04/2012

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0064 Utilization

0

{1 %}

150 Device utilisation I×t

l

Read only

l

Device utilisation of the last
180 s operating time

l

C0064 > 100 % triggers
warning OC5

l

C0064 > 110 % limits the ouput
current of the controller to
67 % of the maximum current
in C0022

^
8.2−25

^
8.2−40

C0150 Status word

Bit00

Bit08

Status code

Read only
Decimal status word for
networking via automation
interface (AIF)

l

Binary interpretation indicates
the bit states

See System
Manual
(extension)

Bit01

IMP

Bit09

Status code

Bit02

Bit10

Status code

Bit03

Bit11

Status code

Bit04

Bit12

Warning

Bit05

Bit13

Message

Bit06

n = 0

Bit14

Bit07

CINH

Bit15

9.1.2

Diagnostics

Display codes for diagnostics

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0093 Drive ident

Controller identification

l

Read only

0

Invalid

Defective power section

1

None

No power section

14
...
20

9335VC 400V
...
9383VC 400V

Display of the controller used

21
...
28

9334VC 500V
...
9383VC 500V

9321
...
9333

9321 VC
...
9333VC

C0099 S/W version

x.y

Software version

l

Read only

x
y

Main version
Subversion

Description

Advertising