2 parameter setting, Parameter setting, Ȧȡ ȣ – Lenze EVF9383 User Manual

Page 28: Ȧȣ ȥ, Safety instructions, Thermal motor monitoring parameter setting

Advertising
background image

Safety instructions

Thermal motor monitoring
Parameter setting

2

2.2
2.2.2

l

2.2−2

EDSVF9383V EN 7.1−04/2012

2.2.2

Parameter setting

Parameter setting

Code

Meaning

Value range

Lenze setting

C0066

Display of the I

2

xt utilisation of the

motor

0 ... 250 %

C0120

Threshold: Triggering of an "OC6" error

0 ... 120 %

0 %

C0127

Threshold: Triggering of an "OC8" error

0 ... 120 %

0 %

C0128

Thermal time constant of the motor

0.1 ... 50.0 min

5.0 min

C0606

Response to "OC8" error

Trip, warning, off

Warning

t

+ * (C0128) @ ln

ȧ

ȡ
Ȣ

1

*

y

) 1

ǒ

IM

Ir

Ǔ

2

@ 100

ȧ

ȣ
Ȥ

I

M

Actual motor current

I

r

Rated motor current

y

C0120 or C0127

ƒ The thermal capacity of the motor is expressed by the thermal motor

time factor (C0128). Please see the rated data of the motor for the
value or ask the manufacturer of the motor.

Diagram for the determination of the release times of a motor with a
thermal motor time factor of 5 min:

I

= 3 × I

mot

r

0

50

100

120

0

100

200

300

400

500

600

700

800

900

1000

t [s]

I t [%]

2

I

= 2 × I

mot

r

I

= 1.5 × I

mot

r

I

= 1 × I

mot

r

9300std105

Fig. 2.2−1

I

2

× t−monitoring: Release times for different motor currents and trigger

thresholds

Imot

Motor current

I

r

Rated motor current

I

2

t

I

2

t load

T

Time

Calculating the release time

Reading the release time off
the diagram