Configuration

Code table

8

8.5

l

8.5−44

EDSVF9383V EN 4.0−03/2006

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0738 Sampling

period

3

3

1 ms

Oscilloscope function

l

Time base

See System
Manual
(extension)

4

2 ms

5

5 ms

6

10 ms

7

20 ms

8

50 ms

9

100 ms

10

200 ms

11

500 ms

12

1 s

13

2 s

14

5 s

15

10 s

16

20 s

17

50 s

18

1 min

19

2 min

20

5 min

21

10 min

C0739 Number of

channels

4

1

{1}

4 Function block OSZ

l

Switching on/off the channels
– 1 = channel 1
– 2 = channel 1 + 2
– 3 = channel 1 ... 3
– 4 = channel 1 ... 4

See System
Manual
(extension)

C0740

0

Oscilloscope function

l

Reading data memory

1 Read start

position

0

0

{1}

65535

l

Provides a pointed access to a
storage block

2 Enable/inhibit

data reading

0

0

No data reading

1

Data reading

C0741 STATUS

0

1000000000 Function block OSZ

l

Read only

See System
Manual
(extension)

1 Version
2 Memory size
3 Data width
4 Number of

channels

C0742 Data block

length

8

0

{1}

65536 Function block OSZ

C0743 Read data

block length
(OSZ)

0

65535 Function block OSZ

l

Read only

l

Reading an 8 byte data block

C0744 Memory depth

3

0

512 measured values

Oscilloscope function

l

Adapt memory capacity to the
measurement task

1

1024 measured values

2

1536 measured values

3

2048 measured values

4

3072 measured values

5

4096 measured values

6

8192 measured values