6 control terminals, 1 important notes, Control terminals – Lenze EVF9383 User Manual

Page 99: Important notes

Advertising
background image

Control terminals

Important notes

5.6

5.6.1

l

5.6−1

EDSVF9383V EN 7.1−04/2012

5.6

Control terminals

5.6.1

Important notes

(

Stop!

The control card will be damaged if

ƒ

the voltage between X5/39 and PE or X6/7 and PE is greater
than 50 V,

ƒ

the voltage between voltage source and X6/7 exceeds 10 V
(common mode) in case of supply via external voltage source.

Limit the voltage before switching on the drive controller:

ƒ

Connect X5/39, X6/2, X6/4 and X6/7 directly to PE or

ƒ

use voltage−limiting components.

ƒ For trouble−free operation, the control cables must be shielded:

– Connect the shield of digital input and output cables at both ends.
– Connect the shield of analog input and output cables at one end (at

the drive controller).

– For lengths of 200 mm and more, use only shielded cables for analog

and digital inputs and outputs. Under 200 mm, unshielded but
twisted cables may be used.

3

1

0

2

9300vec063

Fig. 5.6−1

Connection of the cable shield with shield clip and strain relief with cable binder

0 Shield sheet

1 Fasten shield sheet with two screws M4 × 12 mm at the bottom of the

control card

2 Connect cable shield with shield clip to the shield sheet

3 Provide a strain relief of the control cable at the shield sheet by means of a

cable binder

How to connect the shield

Advertising