Configuration – Lenze EVF9383 User Manual

Page 222

Advertising
background image

Configuration

Function blocks
Master frequency input (DFIN)

8

8.2
8.2.2

l

8.2−6

EDSVF9383V EN 7.1−04/2012

In C0427 the different modes for the evaluation of the input signals can be
selected.

C0427 = 0 (phase−displaced signal sequence)

O
O

B
B

Z
Z

Fig. 8.2−3

Phase−displaced signal sequence (CW rotation)

Clockwise
rotation

Track A leads track B by 90 ° (positive value at DFIN−OUT)

Counter−clock
wise rotation

Track A lags track B by 90 ° (negative value at DFIN−OUT)

C0427 = 1 (control of the direction of rotation via track B)

O
O

B
B

Z
Z

Fig. 8.2−4

Control of direction of rotation via track B

Clockwise
rotation

Track A transmits the speed
Track B = LOW (positive value at DFIN−OUT)

Counter−clock
wise rotation

Track A transmits the speed
Track B = HIGH (negative value at DFIN−OUT)

C0427 = 2 (control of speed and direction of rotation via track A or track B)

O
O

B
B

Z
Z

Fig. 8.2−5

Control of speed and direction of rotation via track A or track B

Clockwise
rotation

Track A transmits the speed and direction of rotation (positive
value at DFIN−OUT)
Track B = LOW

Counter−clock
wise rotation

Track B transmits the speed and direction of rotation (negative
value at DFIN−OUT)
Track A = LOW

Evaluating input signals