Configuration

Code table

8

8.5

l

8.5−18

EDSVF9383V EN 4.0−03/2006

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0183 Diagnostics

Diagnostics

l

Display only

l

If several items or fault or
status information are to be
shown, the information with
the smallest number is
displayed

^
7.2−10

0

No fault

101

Initialisation

102

TRIP/fault

103

Emergency stop

104

IMP message

105

Power OFF

Function is not supported

111

Operation inhibit via C0135

112

Operation inhibit via AIF

113

Operation inhibit via CAN

121

Controller inhibited via X5/28

122

Controller inhibited internally
(DCTRL−CINH1)

123

Controller inhibited internally
(DCTRL−CINH2)

124

Controller inhibited via

sat the

keypad

125

Controller inhibited via AIF

126

Controller inhibited via CAN

141

Switch−on inhibit

142

Pulse inhibit

c

151

Quick stop via MCTRL−QSP

152

Quick stop via

s at the keypad

153

Quick stop via AIF

154

Quick stop via CAN

161

DC injection braking via terminal

162

DC injection braking via C0135

163

DC injection braking via AIF

164

DC injection braking via CAN

170

Motor parameter identification is
active

250

Warning is active (C0168)

C0190 NSET arit

0

0

OUT = C46

Arithmetic function, function
block NSET
Connects main setpoint (C0046)
and additional setpoint (C0040)

See System
Manual
(extension)

1

C46 + C49

2

C46 − C49

3

C46 * C49

4

C46 / C49

5

C46/(100 − C49)

Advertising