Configuration

Function blocks

Master frequency ramp−function generator (DFRFG)

8

8.2

8.2.4

l

8.2−15

EDSVF9383V EN 7.1−04/2012

(

Stop!

Do not operate the drive with this function at the torque
limitation M

max

, I

max

.

The profile generator creates ramps which automatically compensate the
resulting phase displacement. If you do not need this compensation, set
DFRFG−RESET = HIGH.

t

DFRFG-IN

C0752

C0751

C0751

C0755

DFRFG-SYNC

t

DFRFG-OUT

Fig. 8.2−10

Synchronisation on DFRFG

C0751

Setting the deceleration and acceleration time

C0752

Setting the maximum speed

C0755

Setting the switching point

When the actual angle has reached its setpoint and the output signal
corresponds to the input signal, the drive runs in synchronism and the
output DFRFG1−SYNC is set to HIGH. At the same time the profile generator
is switched to the inactive state.

Fig. 8.2−11

Speed−time diagram DFRFG

The number of increments at DFRFG1−IN (master drive) defines the set
phase. The set phase can be displayed as a path. The speed−time diagram
shows the distance covered (angle) as the area below the speed profile.
When synchronisation is reached, master and slave have covered the same
distance (phase).

Profile generator