Configuration – Lenze EVF9383 User Manual

Page 230

Advertising
background image

Configuration

Function blocks
Master frequency ramp−function generator (DFRFG)

8

8.2
8.2.4

l

8.2−14

EDSVF9383V EN 7.1−04/2012

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0758

s

CFG: IN

1000 FIXEDPHI−0

^ Selection list 4

Configuration of input signal,
function block DFRFG1

l

Speed/phase setpoint signal

^
8.2−13

C0759

s

CFG: QSP

1000 FIXED0

^ Selection list 2

Configuration of digital input
signal, function block DFRFG1

l

HIGH = quick stop active

C0760

s

CFG: STOP

1000 FIXED0

^ Selection list 2

Configuration of input signal,
function block DFRFG1

l

HIGH = Status of the profile
generator is maintained,
setpoint is saved

C0761

s

CFG: RESET

1000 FIXED0

^ Selection list 2

Configuration of input signal,
function block DFRFG1

l

HIGH = resetting the
integrators

C0764

0

1 Function block DFRFG1

l

Display of the signals linked in
C0759, C0760 and C0761

1 DIS: QSP
2 DIS: STOP
3 DIS: RESET

C0765 DIS: IN

−32767

{1 rpm}

32767 Function block DFRFG1

l

Display of the signal linked in
C0758