Rockwell Automation Publication 1756-UM535D-EN-P - November 2012

3

Summary of Changes

This publication contains new and updated information. Changes throughout

this revision are marked by change bars, as shown to the right of this paragraph.

New and Updated

Information

This table contains the changes made to this publication revision.

Table 1 - New and Updated Information

Topic

Page

This publication includes the addition of the 1756-RM2/A and 1756-RM2XT modules.

1756-RM2/A or 1756-RM2XT modules can only be used with other 1756-RM2/A or

1756-RM2XT modules. You cannot mix 1756-RM2/A and 1756-RM2XT modules with

1756-RM/A, 1756-RM/B or 1756-RMXT modules.
References throughout the manual to specific redundancy module catalog numbers

have been replaced with ‘redundancy module.’

This manual includes SIL2 application information.

13

Features of enhanced redundancy system using 1756-RM2/A module.

16

Replace 1756-RM/B redundancy modules with 1756-RM2/A redundancy modules

without initiating a switchover.
Fiber channels will experience a delay during a switchover, but will remain synched.

20

1756-RM2/A restrictions.

22

Added 1756-RM2/A and 1756-RM2XT information; important revision information

changes for the 1756-RM2/A and 1756-RM2XT modules.

24

The revision has been updated wherever the 1756-L7x controller appears in this manual

to 19.053.

27

Added new firmware bundles 20.054_kit1, 19.053_kit1, and 19.081_kit1.

49

Use newest version of RMCT when using 1756-RM2/A redundancy module.

54

Added the 1756-RM2/A and 1756-RM2XT modules and installation requirements.

57

Added the statement: 1756-RM2/A or 1756-RM2XT modules can only be used with

other 1756-RM2/A or 1756-RM2XT modules. You cannot mix 1756-RM2/A and 1756-

RM2XT modules with 1756-RM/A, 1756-RM/B or 1756-RMXT modules.

57

Environment and Enclosure change.

58

Small form-factor pluggable warning.

59

Added new 1756-RM2/A and 1756-RM2XT module graphics.

61

Added installation instructions.

62

Added information about connecting fiber-optic cable to redundancy channels and

using redundant fiber cabling.

64

Updated fiber-optic cable information for new redundancy modules.

67

Updated the graphics for the redundant fiber-optic cable.

68

Updated the graphics for the redundant fiber-optic cable.

69

Using dual fiber ports with the 1756-RM2 redundancy modules

138

Crossload times when using a 1756-L7x and a 1756-RM2/A redundancy module.

151

Using a 1756-L7x controller with a 1756-RM2/A redundancy module.

152

Status indicators for 1756-RM2/A and 1756-RM2XT.

200

1756-RM2/A and 1756-RM2XT status indicators.

227

CH1 status indicator.

229

CH2 status indicator.

229