Programming Model

Real-Time Clock

11-11

RTCISR

RTC Interrupt Status Register

0x(ff)FFFB0E

BIT

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

BIT

0

RIS7

RIS6

RIS5

RIS4

RIS3

RIS2

RIS1

RIS0

HR

1HZ

DAY

ALM

MIN

SW

TYPE

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

RESET

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0x0000

Table 11-8. RTC Interrupt Status Register Description

Name

Description

Setting

RIS7
Bit 15

Real-Time Interrupt Status Bit 7—This bit
shows the status of real-time interrupt 7.

0 = No RIS7 interrupt occurred.
1 = RIS7 interrupt occurred.

RIS6
Bit 14

Real-Time Interrupt Status Bit 6—This bit
shows the status of real-time interrupt 6.

0 = No RIS6 interrupt occurred.
1 = RIS6 interrupt occurred.

RIS5
Bit 13

Real-Time Interrupt Status Bit 5—This bit
shows the status of real-time interrupt 5.

0 = No RIS5 interrupt occurred.
1 = RIS5 interrupt occurred.

RIS4
Bit 12

Real-Time Interrupt Status Bit 4—This bit
shows the status of real-time interrupt 4.

0 = No RIS4 interrupt occurred.
1 = RIS4 interrupt occurred.

RIS3
Bit 11

Real-Time Interrupt Status Bit 3—This bit
shows the status of real-time interrupt 3.

0 = No RIS3 interrupt occurred.
1 = RIS3 interrupt occurred.

RIS2
Bit 10

Real-Time Interrupt Status Bit 2—This bit
shows the status of real-time interrupt 2.

0 = No RIS2 interrupt occurred.
1 = RIS2 interrupt occurred.

RIS1
Bit 9

Real-Time Interrupt Status Bit 1—This bit
shows the status of real-time interrupt 1.

0 = No RIS1 interrupt occurred.
1 = RIS1 interrupt occurred.

RIS0
Bit 8

Real-Time Interrupt Status Bit 0—This bit
shows the status of real-time interrupt 0.

0 = No RIS0 interrupt occurred.
1 = RIS0 interrupt occurred.

Reserved
Bits 7–6

Reserved

These bits are reserved and should be set to 0.

HR
Bit 5

Hour Flag—This bit is set on every increment
of the hour counter in the TOD clock.

0 = No 1-hour interrupt occurred.
1 = A 1-hour interrupt occurred.

1HZ
Bit 4

1 Hz Flag—If enabled, this bit is set on every
increment of the second counter in the TOD
clock.

0 = No 1 Hz interrupt occurred.
1 = A 1 Hz interrupt occurred.

DAY
Bit 3

Day Flag—If enabled, this bit is set for every
24-hour clock increment (at midnight)

of the

day counter in the TOD clock, and an interrupt
is posted .

0 = No 24-hour rollover interrupt occurred.
1 = A 24-hour rollover interrupt occurred.

ALM
Bit 2

Alarm Flag—If this bit is enabled, an alarm
flag is set on a compare match between the
real-time clock and the alarm register’s value.

Note:

The alarm will recur every 24 hours.

For a single alarm, clear the interrupt enable in
the interrupt service routine.

0 = No alarm interrupt occurred.
1 = An alarm interrupt occurred.