12-6

MC68VZ328 User’s Manual

Programming Model

12.2

Programming Model

The following sections provide programming information about the settings of the two 16-bit timers in the
GP timers module. Because the two timers are identical, the register description and the associated table
describing the register settings apply to both registers.

12.2.1

Timer Control Registers 1 and 2

Each timer control (TCTLx) register controls the overall operation of its corresponding GP timer. The
settings for the registers are described in Table 12-2. The TCTL registers control the following:

Selecting the free-running or restart mode after a compare event

Selecting the capture trigger event

Controlling the output compare mode

Enabling the compare event interrupt

Selecting the prescaler clock source

Enabling and disabling the GP Timer

TCTL1

Timer Control Register 1

0x(FF)FFF600

TCTL2

Timer Control Register 2

0x(FF)FFF610

BIT

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

BIT

0

FRR

CAP

OM

IRQEN

CLKSOURCE

TEN

TYPE

rw

rw

rw

rw

rw

rw

rw

rw

rw

RESET

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0x0000

BIT

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

BIT

0

FRR

CAP

OM

IRQEN

CLKSOURCE

TEN

TYPE

rw

rw

rw

rw

rw

rw

rw

rw

rw

RESET

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0x0000

Table 12-2. Timer Control Register Description

Name Description

Setting

Reserved
Bits 15–9

Reserved

These bits are reserved and should be set to 0.

FRR
Bit 8

Free-Running/Restart—This bit controls the
counter mode of operation after a compare
event occurs. In free-running mode, the
counter continues after the compare. In restart
mode, the counter resets to 0x0000 and
resumes counting.

0 = Restart mode (default).
1 = Free-running mode.