Timer Capture Registers 1 and 2

Each timer capture register (TCRx) stores the counter value when a capture event occurs. The settings for
the registers are described in Table 12-5.

TCR1

Timer Capture Register 1

0x(FF)FFF606

TCR2

Timer Capture Register 2

0x(FF)FFF616

BIT 15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

BIT 0

CAPTURE

TYPE

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

RESET

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0x0000

BIT 15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

BIT 0

CAPTURE

TYPE

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

RESET

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0x0000

Table 12-5. Timer Capture Register Description

Name Description

Setting

CAPTURE
Bits 15–0

Capture Value—This field stores the counter
value that existed at the time of the capture
event.

This field has a valid range 0x0000 to 0xFFFF.

Advertising