8 rtc interrupt enable register, Table 11-9, Real-time interrupt frequency settings -12 – Motorola MC68VZ328 User Manual

Page 222

Advertising
background image

11-12

MC68VZ328 User’s Manual

Programming Model

11.2.8

RTC Interrupt Enable Register

The RTC interrupt enable register (RTCIENR) is used to enable the interrupts in the RTCSIR if the
corresponding bit is set. The settings for the RTCIENR register are described in Table 11-10 on
page 11-13. For
information about the frequency of the real-time interrupts, refer to Table 11-9.

MIN
Bit 1

Minute Flag—If enabled, this bit is set every
increment of the minute counter in the TOD
clock.

0 = No 1-minute interrupt occurred.
1 = A 1-minute interrupt has occurred.

SW
Bit 0

Stopwatch Flag—If enabled, the stopwatch
flag is set when the stopwatch minute count-
down times out.

0 = The stopwatch did not time out.
1 = The stopwatch timed out.

Table 11-9. Real-Time Interrupt Frequency Settings

Real-Time

Interrupt

Frequency

32.768 kHz

Reference Clock

38.4 kHz

Reference Clock

RFE7

512 Hz

1.9531 ms

600 Hz

1.6666 ms

RFE6

256 Hz

3.9062 ms

300 Hz

3.3333 ms

RFE5

128 Hz

7.8125 ms

150 Hz

6.6666 ms

RFE4

64 Hz

15.625 ms

75 Hz

13.3333 ms

RFE3

32 Hz

31.25 ms

37.5 Hz

26.6666 ms

RFE2

16 Hz

62.5 ms

18.75 Hz

53.3333 ms

RFE1

8 Hz

125 ms

9.375 Hz

106.6666 ms

RFE0

4 Hz

250 ms

4.6875 Hz

213.3333 ms

Table 11-8. RTC Interrupt Status Register Description (Continued)

Name

Description

Setting

Advertising