Functional description, Operation – Nortel Networks Circuit Card 311 User Manual

Page 1003

Advertising
background image

Operation

1003

Functional description

The NTCK16AX and NTCK16BX generic Central Office trunk cards support
up to eight analog Central Office trunks. They can be installed in any IPE
slot.

Both cards are exactly the same except for the Periodic Pulse Metering
(PPM) feature. The NTCK16AX card supports internal 12/16 kHz PPM
but the NTCK16BX card does not.

Common features

The NTCK16AX and NTCK16BX generic Central Office trunk cards:

support the North American loss plan

support loop start signalling

support busy tone detection and supervision on a per unit basis.

support battery reversal detection

provide 4 dB dynamic attenuation pads on a per call basis

allow individual units or the entire board to be disabled by software

provide software selectable A-law or µ-law companding

indicate self-test status during an automatic or manual self-test

provide card-identification for auto configuration, and for determining the
serial number and firmware level of the card

convert transmission signals from analog-to-digital and from
digital-to-analog

provide termination and trans-hybrid balance impedance to match 600

.

Operation

Each NTCK16AX and NTCK16BX generic Central Office trunk card
supports the following:

Loop start operation

Battery reversal detection

Busy tone detection and supervision

Loss Switching

Trunk-to-Trunk connections

Call Disconnect

In addition, the NTCK16AX circuit card supports internal 12/16 kHz PPM
detection.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.

Advertising