Figure 69 set mode (s m): table screen – Nortel Networks Circuit Card 311 User Manual

Page 303

Advertising
background image

Man-Machine E1 maintenance interface software

303

enter just the AB bits (which is copied to the CD bits)

enter a complete ABCD bit pattern

in the case of optional states, a ’N’ or ’n’ can be entered to indicate
that the state is not needed

Note that in D4 Framing for E1, there are no CD bits, so they are ignored.

The user is prompted for ABCD bit values for the following states when
the table mode is selected.

Send and Receive refer to the LEI sending ABCD bits to the CPE (Customer
Provided Equipment) or receiving ABCD bits from the CPE.

Incoming and Outgoing refer to E1 digital link from the CPE point of view.
Incoming is an external call arriving over the digital link and accepted by the
CPE. Outgoing is a call originated by the CPE over the digital link.

Configuring the A/B Bit Signaling table is illustrated in Set Mode (S M): Table
screen and

Figure 70 "Set Mode (S M): Table screen" (page 304)

.

Figure 69
Set Mode (S M): Table screen

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.

Advertising