Functional description

1063

The DTI/PRI obtains its power from the backplane, and draws less than 2
amps on +5 V, 50 mA on +12 V, and 50 mA on -12 V.

The DTI/PRI obtains its power from the backplane, and draws less than 2
amps on +5 V, 50 mA on +12 V, and 50 mA on –12 V.

Foreign and surge voltage protection

Lightning protectors must be installed between an external T1 carrier facility
and the system. For public T1 facilities, this protection is provided by the
local operating company. In a private T1 facility environment (a campus, for
example), the NTAK92 protection assembly can be used.

The NTRB21 circuit card conforms to safety and performance standards for
foreign and surge voltage protection in an internal environment.

Lightning protectors must be installed between an external T1 carrier facility
and the Option 11C cabinet. For public T1 facilities, this protection is
provided by the local operating company. In a private T1 facility environment
(a campus, for example), the NTAK92 protection assembly may be used.

The NTRB21 circuit card conforms to safety and performance standards for
foreign and surge voltage protection in an internal environment.

Lightning protectors must be installed between an external T-1 carrier facility
and the CS 1000 system. For public T-1 facilities, this protection is provided
by the local operating company. In a private T-1 facility environment (a
campus, for example), the NTAK92 protection assembly can be used.

The NTRB21 circuit card conforms to safety and performance standards for
foreign and surge voltage protection in an internal environment.

Functional description

NTRB21 provides the following features and functions:

configurable parameters, including A-Law and µ-Law operation, digital
pads on a per channel basis, and Superframe or Extended Superframe
formats

AMI or B8ZS line coding

1.5 Mb Digital Trunk Interface and 1.5 Mb Primary Rate Interface

1.5 Mb Clock recovery and distribution of reference clocks

DG2 or FDL yellow alarm methods

card status and alarm indication with faceplate-mounted LED

automatic alarm monitoring and handling

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008