867

Foreign and surge voltage protection

Lightning protectors must be installed between an external T1 carrier facility
and the system. For public T1 facilities, this protection is provided by the
local operating company. In a private T1 facility environment (a campus, for
example), the NTAK92 protection assembly can be used.

The NTAK09 circuit card conforms to safety and performance standards for
foreign and surge voltage protection in an internal environment.

Lightning protectors must be installed between an external T1 carrier facility
and the Option 11C cabinet. For public T1 facilities, this protection is
provided by the local operating company. In a private T1 facility environment
(a campus, for example), the NTAK92 protection assembly may be used.

The NTAK09 circuit card conforms to safety and performance standards for
foreign and surge voltage protection in an internal environment.

Lightning protectors must be installed between an external T-1 carrier facility
and the CS 1000 system. For public T-1 facilities, this protection is provided
by the local operating company. In a private T-1 facility environment (a
campus, for example), the NTAK92 protection assembly can be used.

The NTAK09 circuit card conforms to safety and performance standards for
foreign and surge voltage protection in an internal environment.

Functional description

NTAK09 provides the following features and functions:

configurable parameters, including A-Law and µ-Law operation, digital
pads on a per channel basis, and Superframe or Extended Superframe
formats

AMI or B8ZS line coding

1.5 Mb Clock recovery and distribution of reference clocks

DG2 or FDL yellow alarm methods

card status and alarm indication with faceplate-mounted LEDs

automatic alarm monitoring and handling

Card-LAN for maintenance communication

loopback capabilities for both near-end and far-end

echo canceler interface

integrated trunk access (both D-channel and in-band A/B signaling can
be mixed on the same PRI)

faceplate monitor jacks for T1 interface