Clock configurations

Clock Controllers can be used in a single or a dual CPU system.

A single CPU system has one Clock Controller card. This card can receive
reference clocks from two sources referred to as the primary and secondary
sources. These two sources can originate from a PRI2, DTI2, etc. PRI2
cards such as the NT8D72BA are capable of supplying two references of
the same clock source. These are known as Ref1 (available at J1) and Ref2
(available at J2) on the NT8D72BA.

The NT5D97 card is capable of supplying two references from each clock
source, for example, four references in total. NT5D97 can supply Clk0 and
Clk1 from Unit 0 and Clk0 and Clk1 from Unit 1. Either Unit 0 or Unit 1 can
originate primary source, as shown in

Figure 97 "Clock Controller - Option

1" (page 355)

through

Figure 100 "Clock Controller - Option 4" (page 358)

.

There is one Clock Controller cable required for the DDP2 card, which
is available in four sizes; this is the NTCG03AA/AB/AC/AD. Refer to

"Reference clock cables" (page 337)

for more information.

Table 161 "Clock Controller options - summary" (page 353)

summarizes the

clocking options.

Table 162 "Clock Controller options - description" (page

354)

explains the options in more detail.

Table 161
Clock Controller options - summary

CC Option

CPU Type

Notes

Option 1

Single

Ref from P0 on Clk0

Ref from P1 on Clk0

Option 2

Dual

Ref from P0 on Clk0

Ref from P0 on Clk1

Option 3

Dual

Ref from P1 on Clk0

Ref from P1 on Clk1

Option 4

Dual

Ref from P0 on Clk0

Ref from P0 on Clk1

Ref from P1 on Clk0

Ref from P1 on Clk1

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008