Table 104 mmi commands and command sets – Nortel Networks Circuit Card 311 User Manual

Page 234

Advertising
background image

234

NT5D11 and NT5D14 Lineside T1 Interface cards

Notation Used:

CAPS - Required Letters

[ ] - Optional

| - Either/Or

Each of these commands can be executed by typing the first letter of the
command or by typing the entire command. Command sets are entered
by typing the first letter of the first command, a space, and the first letter
of the second command or by typing the entire command.

Table 104 "MMI

commands and command sets" (page 234)

shows all the possible command

sets, listed in alphabetical order. These commands are described by subject
later in this section.

Table 104
MMI commands and command sets

Command

Description

A D

Alarm Disable
Disables all alarms

A E

Alarm Enable
Enables all alarms

C A

Clear Alarm
Clears all alarms, terminates line processing, and resets the T1 bit error rate and
frame slip counters

C A L

Clear Alarm Log
Clears the alarm log

C E

Clear Error
Clears the error counter for the T1

D A [P]

Display Alarms [Pause]
Displays the alarm log – a list of the most recent 100 alarms along with time and
date stamps

D C

Display Configuration
Displays the configuration settings for the cards including:

the serial number of the card

MMI firmware version

date and time

alarm enable/disable setting

self-clearing enable/disable setting

settings entered in Set Configuration

dip switch settings

D H [P]

Display History [Pause]
Displays performance counters for the past 24 hours.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.