Configuring the esdi card – Nortel Networks Circuit Card 311 User Manual

Page 1097

Advertising
background image

Configuring the ESDI card

1097

Signal source

Pin number

Signal functions

To DCE

From

DCE

EIA

circuit

(lead)

Data

2
3

13
16

Transmitted data – lead A

Received data – lead A

Transmitted data – lead B

Received data – lead B

3

3

3

3

BA (A)
BB (A)
BA (B)
BB (B)

Control

4
5
6
8

20

Request to send (RTS)

Clear to send (CTS)

Data set ready (DSR)

Carrier detect (CD)

Data terminal ready (DTR)

3



3

3
3
3

CA
CB
CC
CF
CD

Timing

12

Transmitter signal element

timing (DTE) – lead B

3

DD (B)

14

Transmitter signal element

timing (DCE) – lead B

3

DB (B)

15

Transmitter signal element

timing (DCE) – lead A

3

DB (A)

17

Transmitter signal element

timing (DTE) – lead A

3

DD (A)

23

Receiver signal element timing

(DCE) – lead A

3

DA (A)

24

Receiver signal element timing

(DCE) – lead B

3

DA (B)

Note: Pins not used are 9, 10, 11, 18, 19, 21, 22, 25.

Configuring the ESDI card

Configuring the ESDI card consists of setting the port addresses using the
address selection switch and setting the port interface options using the
jumper blocks. The system software must then be configured to recognize
the ESDI card.

Figure 312 "ESDI card option switch locations" (page

1099)

shows the location of all option switches and jumper sockets on the

ESDI card.

Address switch settings

The two ESDI ports on the card are addressed in pairs such as 0 and 1, 2
and 3, and so on). The address is set using switch S2. The switch settings
used to select the address vary depending on whether the card is Style A or
Style B. The "Style" can be read on the printed circuit board silk screen. The
address of the card is set to match the device address defined in software.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.

Advertising