Table 22 nt6d42 jumper locations p4 and p5, Table 23 nt6d42 jumper location j7, Table 24 nt6d42 sw1 – Nortel Networks Circuit Card 311 User Manual

Page 90

Advertising
background image

90

Option settings

Table 21
NT6D42 recommended options for North American and British Telecom

Application

Ringing
frequency

Ringing
voltage

Jumper locations

Ringing output

North America

20 Hz

86 V ac

P5

High voltage

message waiting

Low impedance

British Telecom

25 Hz

80 V ac

P4

No high voltage

message waiting

Low impedance

Table 22
NT6D42 jumper locations P4 and P5

High voltage message waiting

Pin location

Disable

Jumper in P4

Enable

Jumper in P5

Note: One jumper must be installed.

Table 23
NT6D42 jumper location J7

Ringing output

Jumper location J7

Low impedance (normal)

Connect pins 1 and 2

High impedance (Australia)

Connect pins 2 and 3

Table 24
NT6D42 SW1

Ringing frequency (Hz)

Position SW1

20

1

25

2

50

3

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.

Advertising