Nortel Networks Circuit Card 311 User Manual
Page 572

572
NT8D14 Universal Trunk card
The faceplate of the card is equipped with a red Light Emitting Diode (LED).
See
Figure 141 "Universal trunk card - faceplate" (page 573)
. When an
NT8D14 Universal Trunk card is installed, the LED remains lit for two to
five seconds while the self-test runs. If the self-test is successful, the LED
flashes three times and remains lit. When the card is configured and
enabled in software, then the LED goes out. If the LED flashes continuously
or remains weakly lit, replace the card.
The universal trunk card mounts in any IPE slot. The trunk and common
multiplexing circuitry is mounted on a 31.75 cm by 25.40 cm (12.5 in. by
10 in.) printed circuit board.
The universal trunk card connects to the backplane through a 160-pin
connector shroud. The backplane is cabled to the I/O panel, which is
cabled to the Main Distribution Frame (MDF) by 25-pair cables. External
equipment, such as recorded announcement machines, paging equipment,
and central office facilities, connect to the card at the MDF.
See Communication Server 1000M and Meridian 1 Large System
Installation and Configuration (NN43021-310) for termination and
cross-connect information.
The faceplate of the card is equipped with a red LED. See
"Universal trunk card - faceplate" (page 574)
. When a universal trunk card is
installed, the LED remains lit for 2 to 5 seconds while the self-test runs. If the
self-test completes successfully, the LED flashes three times and remains lit
until the card is configured and enabled in software, then the LED goes out.
If the LED flashes continuously or remains weakly lit, replace the card.
The trunk and common multiplexing circuitry is mounted on a 31.75 cm by
25.40 cm (12.5 in. by 10 in.) printed circuit board.
The NT8D14 Universal Trunk Card connects to the backplane through
a 160-pin connector shroud. External equipment, such as recorded
announcement machines, paging equipment, and Central Office facilities,
connect to the card at the back of the Media Gateway using a 25-pin
connector. See the Communication Server 1000M and Meridian 1 Large
System Installation and Configuration (NN43021-310) for termination and
cross-connect information.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.