Figure 256 pad orientation, Table 306 pad switching algorithm, Table 306 "pad – Nortel Networks Circuit Card 311 User Manual

Page 791

Advertising
background image

Configuration

791

See

Table 306 "Pad switching algorithm" (page 791)

for the pad switching

control for the various through connections and the actual port-to-port loss
introduced for connections between the E and M Trunk card and any other
IPE port designated as Port B.

Figure 256 "Pad orientation" (page 791)

shows the pad switching orientation.

Table 306
Pad switching algorithm

Port B pads

E and M Trunk Pads

Port-to-port loss (dB)

Port B

Transmit

D to A

Receive

A to D

Transmit

D to A

Receive

A to D

Port B to

E and M

E and M to

Port B

IPE line

N/A

N/A

Out

In

2.5

3.5

Universal
trunk (TRC)

Out

Out

In

In

0

0

IPE TIE (VNL)

In

Out

In

Out

0

0

Note: Transmit and receive designations are from and to the system. Transmit is from the system to
the external facility (digital-to-analog direction in the E and M Trunk card). Receive is to the system
from the external facility (analog-to-digital direction in the E and M Trunk card).

Loss parameters are selected on the E and M trunk card by a switchable
pad controlled by Codec emulation software. For convenience in this
discussion, the pads settings are called "in" and "out." Pad settings are
determined by the three factors listed below: the first two are under direct
user control; the third is controlled indirectly.

Figure 256
Pad orientation

Class of service is assigned in LD 14.

Facility termination is selected (2-wire or 4-wire) in LD 14 (the 2-wire
setting provides 0.5 dB more loss in each direction of transmission for
echo control).