Figure 10
IPE trunk cards installed in an NT8D37 IPE module

3

Install the cable that connects the backplane connector on the IPE
module to the module I/O panel.

4

Connect a 25-pair cable from the module I/O panel connector to the
Main Distribution Frame (MDF).

5

Connect the trunk card output to the selected terminal equipment
at the MDF.

6

Configure the individual trunk interface unit using the Trunk
Administration program (LD 14) and the Trunk Route Administration
program (LD 16).

—End—

Once these steps are complete, the trunk card is ready for use.

Operation

This section describes how trunk cards fit into the CS 1000E, CS 1000M,
and Meridian 1 architecture, the buses that carry signals to and from the
trunk cards, and how they connect to terminal equipment. See

Table 7

"Differences between IPE parameters" (page 48)

for IPE parameters.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008