CAUTION

The static discharge bracelet located inside the cabinet must be
worn before handling circuit cards. Failure to wear the bracelet
can result in damage to the circuit cards.

Procedure 15

Installing the NT5D97

Step

Action

1

Determine the cabinet and shelf location where the NT5D97 is to
be installed. The NT5D97 can be installed in any card slot in the
Network bus.

2

Unpack and inspect the NT5D97and cables.

3

If a DDCH is installed, refer to the section

Procedure 16 "Removing

the NT5D97" (page 360)

.

4

Set the option switches on the NT5D97 card before installation.
Refer to

"NT5D97AA/AB DIP switch settings" (page 341)

.

The ENB/DIS (enable/disable faceplate switch) must be OFF (DIS)
when installing the NT5D97, otherwise a system initialize can occur.
The ENB/DIS on the NT5D97 corresponds to the faceplate switch
on the QPC414 Network card.

5

Install NT5D97 card in the assigned shelf and slot.

6

Set the ENB/DIS faceplate switch to ON.

If the DDCH is installed, the DDCH LED should flash three times.

7

If required, install the I/O adapters in the I/O panel.

8

Run and connect the NT5D97 cables

CAUTION

Clock Controller cables connecting the Clock Controller
and NT5D97 card must NOT be routed through the center
of the cabinet past the power harness. Instead they should
be routed around the outside of the equipment shelves.

9

If required, install connecting blocks at the MDF or wall mounted
cross-connect terminal.