Nortel Networks Circuit Card 311 User Manual

Page 463

Advertising
background image

Hayes dialing

463

Character echo control

On-hook/off-hook control

Detect off-line escape sequence

Return to on-line

Initiate Remote Digital Loopback

Terminate Remote Digital Loopback

Modify S Registers S0 through S12

Display S Registers S0 through S12

Support all S Registers except: S6, S7, S9, and S11

The Hayes dialing mode supports the following AT Dialing commands.

Initiating conditions

The DAC responds to commands only when the following initial requirements
are met:

the DAC is active

the DAC has successfully received the downloaded parameters

the user equipment is active, and, if operating in RS-232-C mode

— the DCE mode is DTR (unless Forced DTR has been software

selected)

— the DTE mode, and RI has cycled the appropriate number of times

and DCD is asserted on by the modem

Note: In Gateway mode, DCD must be asserted on. In modem mode,
only RI must be on. The DAC asserts DTR to the modem, and awaits
DCD from the modem.

Input requirements

All input must be in the same case (upper or lower).

The Hayes repeat command, A/, is used to immediately execute the last
command entered. The terminator character need not be entered. A
complete discussion of the Repeat command can be found later in this
document.

Where a Dial Number is expected, you may enter the characters 0-9, #, and
comma (,). The characters @, P, R, T, and W are accepted, but ignored.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.