Table 25 nt6d42cb sw2, Table 26 nt6d42cc sw2 – Nortel Networks Circuit Card 311 User Manual

Page 91

Advertising
background image

NT5D2101/NT9D1102 Core/Network module backplane

91

Table 25
NT6D42CB SW2

SW2

Ringing

voltage

Message waiting

voltage

1

2

3

4

86 V ac

–120 V dc

off

off

off

off

86 V ac

–150 V dc

off

off

off

on

80 V ac

–120 V dc

on

off

off

off

80 V ac

–150 V dc

on

off

off

on

75 V ac

–120 V dc

off

on

off

off

75 V ac

–150 V dc

off

on

off

on

70 V ac

–120 V dc

off

off

on

off

70 V ac

–150 V dc

off

off

on

on

Table 26
NT6D42CC SW2

SW2

Ringing

voltage

Message waiting

voltage

1

2

3

4

86 V ac

–100 V dc

off

off

off

off

86 V ac

–150 V dc

off

off

off

on

80 V ac

–100 V dc

on

off

off

off

80 V ac

–150 V dc

on

off

off

on

75 V ac

–100 V dc

off

on

off

off

75 V ac

–150 V dc

off

on

off

on

70 V ac

–100 V dc

off

off

on

off

70 V ac

–150 V dc

off

off

on

on

NT5D2101/NT9D1102 Core/Network module backplane

Table 27
NT5D2101/NT9D1102 Core/Network module backplane

Jumper

Location

(between slots)

Core/Network 1

Core/Network 0

Note: Berg jumper is located at the bottom of the primary side of the backplane. (This is inside the
card cage assembly.)

JB1

14/15

Jumper plug not installed

Plug installed

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.