Figure 162 "ground start call connection sequence – Nortel Networks Circuit Card 311 User Manual

Page 606

Advertising
background image

606

NT8D14 Universal Trunk card

Figure 162
Ground start call connection sequence - incoming call from CO/FX/WATS

If the threshold count exceeds its limit, an error message is printed and the
trunk is registered as "positively reverse wired." Once identified as positively
reverse wired, the call is presented continuously from the first ring. When a
reverse-wired trunk becomes correctly wired, the first subsequent call clears
the threshold counter and normal ground start processing is implemented.