Installing the data access card, Table 188 dac environmental specifications – Nortel Networks Circuit Card 311 User Manual

Page 479

Advertising
background image

Installing the Data Access card

479

EIA

DB-25
Pin

Signal
abbreviation

Description

DCE
mode

DTE
mode

CC

6

DSR

Data Set Ready

Out

In

AB

7

GND

Signal Ground

CF

8

DCD

Carrier Detect

Out

In

CD

20

DTR

Data Terminal Ready

In

Out

CE

22

RI

Ring Indicator

Out

In

Note: RS-422 leads supported are: Tx (transmit) and Rx (receive).

Environmental

The DAC functions fully when operating within the following specified
conditions. See

Table 188 "DAC environmental specifications" (page 479)

Table 188
DAC environmental specifications

Specification

Operating

Storage

Ambient temperature

0 to 60 degrees C

40 to 70 degrees C

Humidity

5% to 95%

5% to 95%

Reliability

The DAC has a predicted mean time between failure (MTBF) of 8 years at
45 degrees Celsius. The mean time to repair (MTTR) is 1 hour.

Installing the Data Access card

Cabinet system

The DAC is fully supported in any card slot in either the main or expansion
cabinet without any hardware modification. Insert the DAC into any available
card slot and secure it in place using the locklatches.

To cable out the DAC, run a standard 25-pair cable to the cross connect, or
use one of the following breakout cables in conjunction with an Amphenol
50-pin female-to-female gender converter:

QCAD318A50-pin Amphenol to 6 female DB25 connectors

QCAD319A50-pin Amphenol to 6 male DB25 connectors

Note: For Cabinet system, the format to be used in response to the
"TN" prompt must be one of the following:

CC 00 00 UUCC - Card Slot
or CC UUUU - Unit Number

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.

Advertising