Table 17 trunk interface impedance switch settings, Table 18 ring ground switch settings – Nortel Networks Circuit Card 311 User Manual

Page 86

Advertising
background image

86

Option settings

A set of four DIP switches provides selection among three values for
receiver impedance. Use SW8 for Trunk 0; use SW14 for Trunk 1 (see

Table

17 "Trunk interface impedance switch settings" (page 86)

).

Table 17
Trunk interface impedance switch settings

Description

SW8/SW14 Switch Settings

75

off

off

on

off

100

on

off

off

on

120

off

off

off

on

Ring ground switches

A set of four DIP switches selects which Ring lines are connected to ground
(see

Table 18 "Ring ground switch settings" (page 86)

).

Table 18
Ring ground switch settings

Switch

Description

S2 switch setting

1

Trunk 0 Transmit

off - Ring line is not grounded

on- Ring line is grounded

2

Trunk 0 Receive

off - Ring line is not grounded

on - Ring line is grounded

3

Trunk 1 Transmit

off - Ring line is not grounded

on - Ring line is grounded

4

Trunk 1 Receive

off - Ring line is not grounded

on - Ring line is grounded

DCH mode and address select switches

One switch selects an on-board NTBK51AA D-Channel daughterboard
and an external MSDL/DCHI card. Four other switches provide the
daughterboard address (see

Table 19 "DCH mode and address select

switch settings" (page 87)

).

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008