Nt8d15 e and m trunk card, Table 35 nt8d15 e and m trunk card – Nortel Networks Circuit Card 311 User Manual

Page 95

Advertising
background image

NT8D15 E and M Trunk card

95

Table 34
NT8D14 vintages BA/BB cable loop resistance and loss

Cable loop resistance (ohms)

Cable loop loss (dB)
(non-loaded at 1kHz)

Cable length

22 AWG

24 AWG

26 AWG

22 AWG

24 AWG

26 AWG

915 m (3000 ft)

97

155

251

0.9

1.2

1.5

1524 m (5000 ft)

162

260

417

1.6

2.0

2.5

2225 m (7300 ft)

236

378

609

2.3

3.0

3.7

3566 m (11700 ft)

379

607

977

3.7

4.8

6.0

5639 m (18500 ft)

600

960

1544

5.9

7.6

9.4

NT8D15 E and M Trunk card

Table 35
NT8D15 E and M Trunk card

Mode of operation (Note 2)

2-wire trunk

4-wire trunk

DX tip & ring pair

Jumper
(Note 1)

Type I

Paging

Type I

Type II

M—rcv
M—xmt

E—rcv
M—xmt

J1.X

off

off

off

off

Pins 1–2

Pins 2–3

J2.X

on

on
(Note 3)

on

on

off

off

J3.X

off

off

off

off

(Note 4)

(Note 4)

J4.X

off

off

off

off

Pins 2–3

Pins 1–2

J5.X

off

off

off

off

(Note 4)

(Note 4)

J6.X

off

off

off

off

on

on

J7.X

off

off

off

off

on

on

J8.X

off

off

off

off

on

on

J9.X

Pins 2–3

Pins 2–3

Pins 2–3

Pins 2–3

Pins 1–2

Pins 1–2

Note: Jumper strap settings J1.X through J9.X apply to all 4 units; "X" indicates the unit number,
0–3.

Note: Off indicates that no jumper strap is installed on a jumper block.

Note: Paging trunk mode is not zone selectable.

Note: Jumper strap installed in this location only if external loop resistance exceeds 2500 ohms.

Note: Dot next to the jumper block indicates pin 1.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.

Advertising