NT5D11 and NT5D14 Lineside T1 Interface cards

Table 85
Lineside T1 card - environmental specifications

Parameter

Specifications

Operating temperature-normal

15



to +30



C (+59



to 86



F), ambient

Operating temperature-short term

10



to +45



C (+50



to 113



F), ambient

Operating humidity-normal

20% to 55% RH (non-condensing)

Operating humidity-short term

20% to 80% RH (non-condensing)

Storage temperature

–50



to +70



C (–58



to 158



F), ambient

Storage humidity

5% to 95% RH (non-condensing)

Table 86 "Lineside T1 card - environmental specifications" (page 188)

lists

the environmental specifications of the Lineside T1 card.

Table 86
Lineside T1 card - environmental specifications

Parameter

Specifications

Operating temperature-normal

15



to +30



C (+59



to 86



F), ambient

Operating temperature-short term

10



to +45



C (+50



to 113



F), ambient

Operating humidity-normal

20% to 55% RH (non-condensing)

Operating humidity-short term

20% to 80% RH (non-condensing)

Storage temperature

–50



to +70



C (–58



to 158



F), ambient

Storage humidity

5% to 95% RH (non-condensing)

Installation and configuration

Installation and configuration of the Lineside T1 card consists of six basic
steps:

Step

Action

1

Configure the dip switches on the Lineside T1 card for the
environment.

2

Install the Lineside T1 card into the selected card slots in the IPE
shelf.

3

Cable from the I/O panel to the Customer Premise Equipment
(CPE) or CSU, MMI terminal or modem (optional), external alarm
(optional), and other Lineside T1 cards for daisy chaining use of
MMI terminal (optional).

4

Configure the MMI terminal.

Nortel Communication Server 1000