LED indicators

1043

Faceplate buttons

Reset

Reset (RST) generates a hard reset of the card.

Init

Init (INI) generates a manual initialization of the software.

DIP switch

The DIP switch selects the media drive. CF MASTER/POSITION1 selects
the Compact Flash (CF) FMD and HD MASTER/POSITION2 selects the
Hard Drive FMD.

LED indicators

Status LED

The functionality of the Status LED is summarized in the following table.

Table 428
Status LED functionality

LED

Color

CP PM Status

Status

Green

After sysload

Flashing Green

Not implemented

Yellow

Not implemented

Orange

Selftest error

Red

During sysload phase 2

Flashing Red

During sysload phase 1

Off

No power

Active CPU LED

The CP PM can operate in single CPU mode or dual CPU mode. A tri-color
LED indicates the Call Server redundancy status. This LED is not used by
the Signaling Server and is OFF if it is a Signaling Server. The functionality
of the active CPU LED is summarized in the following table.

Table 429
Call server redundancy status

LED

Color

Status

Call server redundancy

Green

Redundant mode, active

Yellow

Redundant mode, standby

Red

Redundant mode, fault (HSP
down)

Off

Standard mode

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008