NTBK50 2.0 Mb PRI card

Software selects A-law or Mu-Law and one of 32 possible PAD values for
each channel. These values are provided in a PROM through which the
data is routed. The idle code for A-law is 54H and for Mu-law is 7FH. The
unequipped code is FFH for both A-law and Mu-law.

As the idle code and unequipped code may be country dependent, the
software instructs the NTBK50 to use different codes for each direction. The
32 digital pads available are illustrated in

Table 406 "Digital Pad - values and

offset allocations" (page 978)

. The values shown are attenuation levels

(1.0dB is 1dB of loss and -1.0dB is 1db of gain).

Table 406
Digital Pad - values and offset allocations

PAD SET 0

PAD SET 1

Offset

PAD

Offset

PAD

0

0.6 dB

0

0.0 dB

1

1.0 dB

1

-1.0 dB

2

2.0 dB

2

-2.0 dB

3

3.0 dB

3

-3.0 dB

4

4.0 dB

4

-4.0 dB

5

5.0 dB

5

-5.0 dB

6

6.1 dB

6

-6.0 dB

7

7.0 dB

7

-7.0 dB

8

8.0 dB

8

-8.0 dB

9

9.0 dB

9

-9.0 dB

10

10.0 dB

10

-10.0 dB

11

11.0 dB

11

spare

12

12.0 dB

12

spare

13

13.0 dB

13

spare

14

14.0 dB

14

Idle Code

15

spare

15

Unassigned Code

The software selects A-Law or Mu-Law and one of 32 possible PAD values
for each channel. These values are provided in a PROM through which the
data is routed. The idle code for A-Law is 54H and for Mu-Law is 7FH. The
unequipped code is FFH for both A-Law and Mu-Law.