Installation and configuration – Nortel Networks Circuit Card 311 User Manual

Page 274

Advertising
background image

274

NT5D33 and NT5D34 Lineside E1 Interface cards

Parameter

Specifications

Storage temperature

–50



to + 70



C (–58



to 158



F), ambient

Storage humidity

5% to 95% RH (non-condensing)

Installation and Configuration

Installation and configuration of the LEI consists of six basic steps:

Step

Action

1

Configure the dip switches on the LEI for the call environment.

2

Install the LEI into the selected card slots.

3

Cable from the I/O panel to the LTU, MMI terminal or modem
(optional), external alarm (optional), and other LEIs for daisy
chaining use of MMI terminal (optional).

4

Configure the MMI terminal.

5

Configure the LEI through the CS 1000 software and verify self-test
results.

6

Verify initial E1 operation and configure MMI (optional).

Steps 1-5 are explained in this section. Step 6 is covered in

"Man-Machine E1 maintenance interface software" (page 292)

.

Installation and configuration of the ELEI follows the same steps.
If enhanced functionality is required, then one additional step is
required:

7

The Meridian 1 line unit(s) associated with the lineside E1 must
be programmed for wireless operation (set WTYP=DECT, and
WRLS=Yes in LD 10) in non–concentrated mode. Refer to Software
Input/Output Reference — Administration
(NN43001-611) details
on LD 10.

—End—

Dip switch settings

Begin the installation and configuration of the LEI by selecting the proper dip
switch settings for the environment. The LEI contains two dip switches, each
containing eight switch positions. They are located in the upper right corner
of the motherboard circuit card as shown in

Figure 59 "LEI card - E1 protocol

dip switch locations" (page 276)

. The settings for these switches are shown

in

Table 115 "LEI card - Switch 1 dip switch settings" (page 277)

through

Table 118 "LEI card - E1 Switch 2 (S2) dip switch settings" (page 279)

.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.