Electrical specifications
137
Power requirements
Table 65 "OPS analog line card - power requirements" (page 137)
shows
the maximum power consumed by the card from each system power supply.
Table 65
OPS analog line card - power requirements
Voltage
Tolerance
Current (max.)
±15.0 V dc
± 5%
150 mA
+8.5 V dc
± 2%
200 mA
+5.0 V dc
± 5%
100 mA
–48.0 V dc
± 5%
350 mA
The +8.5 V dc input is regulated down to +5 V dc for use by the digital logic
circuits. All other power to the card is used by the line interface circuits.
The +8.5 V dc input is regulated down to + 5 V dc for use by the digital logic
circuits. All other power to the card is used by the line interface circuits.
The +8.5 V dc input is regulated down to +5 V dc for use by the digital logic
circuits. All other power to the card is used by the line interface circuits. The
±15.0 V dc inputs to the card are used to power the analog circuits. The +5
V dc from the module power supply is used for the analog hybrid. The
–48.0 V dc input is for the telephone battery. Ringing power for telephones
is 86 Vrms ac at 20 Hz on –48 V dc. The Rsync signal is used to switch
the 20 Hz ringing on and off at the zero cross-over point to lengthen the
life of the switching circuits.
Foreign and surge voltage protection
The NT1R20 OPS analog line card meets UL-1489 and CS03 over-voltage
(power cross) specifications and FCC Part 68 requirements for hazardous
and surge voltage limits.
Table 65 "OPS analog line card - power
shows the maximum power consumed by the
card from each system power supply.
Ringer limitations
The OPS line card supports up to three NE-C4A (3 REN) ringers on each
line for either ONS or OPS applications. See
card - ringer limitations" (page 138)