Table 118 "lei – Nortel Networks Circuit Card 311 User Manual

Page 279

Advertising
background image

Installation and Configuration

279

Table 118
LEI card - E1 Switch 2 (S2) dip switch settings

Characteristic

Selection

Switch

Position

Switch

Setting

Factory

Default

E1 framing

CRC-4 Disabled

CRC-4 Enabled

1

ON

OFF

OFF

E1 coding

AMI

HDB3

2

ON

OFF

OFF

NOT USED

leave ON

3

ON

ON

NOT USED

leave ON

4

OFF

OFF

NOT USED

leave ON

5

OFF

OFF

Line processing on E1 link
failure

On-hook

Off-hook

6

ON

OFF

ON

Daisy-chaining to MMI

YES

NO

7

ON

OFF

OFF

MMI master or slave

Master

Slave

8

ON

OFF

ON

Table 119
ELEI card - E1 Switch 2 (S2) dip switch settings

Characteristic

Selection

Switch

Position

Switch

Setting

Factory

Default

E1 framing

CRC-4 Disabled

CRC-4 Enabled

1

ON

OFF

ON

E1 coding

AMI

HDB3

2

ON

OFF

OFF

NOT USED

leave ON

3

ON

ON

NOT USED

leave ON

4

OFF

OFF

Mode

LEI Mode

ELEI Mode

5

OFF

ON

OFF

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008