Table 219 power requirements – Nortel Networks Circuit Card 311 User Manual

Page 553

Advertising
background image

Electrical specifications

553

Frequency (Hz)

Minimum (dB)

Maximum (dB)

3000

–0.5

1.0

3200

–0.5

1.5

3400

0.0

3.0

Power requirements

Table 219 "Power requirements" (page 553)

provides the power

requirements for the NT8D09 Analog Message Waiting Line card.

Table 219
Power requirements

Voltage
(+/-)

Tolerance

Idle
current

Active
current

Max

+ 12.0 V dc

0.36 V dc

48 mA

0 mA

48
mA

+ 8.0 V dc

0.40 V dc

150 mA

8 mA

280
mA

–48.0 V dc

2.00 V dc

48 mA

40 mA

688
mA

–48.0 V dc

5.00 V dc

0 mA

10 mA
(Note 1)

320
mA

86.0 V ac

5.00 V ac

0 mA

10 mA
(Note 2)

160
mA

–150.0 V dc

3.00 V dc

0 mA

2 mA

32
mA

Note 1: Each active ringing relay requires 10 mA of battery voltage.

Note 2: Reflects the current for ringing a single station set (or DN telephone).
There may be as many as five ringers on each line.

Table 220 "Analog message waiting line card - power requirements" (page
554)

provides the power requirements for the analog message waiting line

card.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.