Figure 70 set mode (s m): table screen, Figure 70 "set – Nortel Networks Circuit Card 311 User Manual

Page 304

Advertising
background image

304

NT5D33 and NT5D34 Lineside E1 Interface cards

Idle SEND – This is the value that the LEI sends (acting as the CO or
PSTN) when the circuit is in the idle state. This value is required.

Idle RECEIVE – This is the value that the LEI expects to see from the CPE
when it is in the idle state. This value is required.

Blocking RECEIVE – This is the value that the LEI expects to see from the
CPE when the customer equipment is in the blocking or fault state and is
unable to accept new calls. Set this value to N if this state is not needed. If
this value is not set to N, then dip switch #2 position 6 determines whether
off-hook or on-hook is sent to the M1/SL100 when this state is entered. See

Table 118 "LEI card - E1 Switch 2 (S2) dip switch settings" (page 279)

.

Figure 70
Set Mode (S M): Table screen

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.