NT1R20 Off-Premise Station Analog Line card

Figure 24
OPS analog line card - jumper block locations

Each line interface unit on the card is equipped with two jumper blocks that
are used to select the proper loop current depending upon loop length.
See

Table 71 "OPS analog line card - configuration" (page 144)

. For units

connected to loops of 460 to 2300 ohms, both jumper blocks must be
installed. For loops that are 460 ohms or less, jumper blocks are not
installed.

Figure 77 "Test parameters screen" (page 312)

shows the location

of the jumper blocks on the OPS analog line card.

Nortel Communication Server 1000

Circuit Card Reference