NT5D33 and NT5D34 Lineside E1 Interface cards

1, depending on how the dip switch for line processing is set (dip switch 2,
position 6). See

Table 118 "LEI card - E1 Switch 2 (S2) dip switch settings"

(page 279)

.

If the MMI detects E1-link failures for any of the other conditions monitored
(out-of-frame, excess frame slips, loss-of-signal, and blue alarm condition),
the LEI automatically performs all alarm level 2 functions. The MMI
also sends a yellow alarm to the far-end LTU. Alarms may be configured
to self-clear when the alarm condition is no longer detected. See

"Set

Clearing" (page 301)

.

All alarms activated produce a record in the alarm log. The alarm log
maintains records for the most recent 100 alarms, and can be displayed,
printed, and cleared. The alarm log displays or prints the alarms in
descending chronological order, beginning with the most recent alarm.
Notifications in the alarm log include the date and time of the alarm’s
occurrence.

E1 Performance Counters and Reports

The MMI maintains performance error counters for the following E1
conditions:

errored seconds

bursty seconds

unavailable seconds

framer-slip seconds

loss-of-frame seconds

The MMI retains E1 performance statistics for the current hour, and for
each hour for the previous 24. For descriptions of these performance error
counters and instructions on how to create a report on them and clear them,
see

"Performance counters and reporting" (page 309)

.

E1 Verification and Fault Isolation Testing

The MMI enables various tests to be performed that either verify that the E1
is working adequately, or help to isolate a problem to the LEI, the E1 link, or
the CPE. For descriptions of all of these tests and instructions on how to
run them, see

"Testing" (page 311)

.

Login and Password

The MMI can be accessed through any TTY, PC running a terminal
emulation program, or modem. After installing the MMI terminal and card
cables, the MMI can be configured.

For single-card installations, it is accessed by entering

L<CR>

to login.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008