Introduction

905

It is consequently located in slots 1 to 9 of the main and IP expansion
cabinets and can support 1.5 Mb, 2.0 Mb, and 2.56 Mb clock recovery rates

Note: The card is restricted to slots 1 through 3 in EMC- type cabinets
(such as NAK11Dx and NTAK11Fx cabinets). It does not work in slots 4
through 10 in these cabinets.

ATTENTION

IMPORTANT!

If an IP Expansion multi-cabinet system is equipped with digital trunk cards, it is
mandatory that at least one trunk card is placed in the Main Option 11C cabinet.
A cabinet that has a digital trunk must have a clock controller.

NTAK20 provides the following features and functions:

phase lock to a reference, generation of the 10.24 Mhz system clock,
and distribution of the clock to the CPU through the backplane

accepts one primary and one secondary reference

primary-to-secondary switchover and auto-recovery

chatter prevention due to repeated switching

error-burst detection and correction, holdover, and free running
capabilities

communication with software

jitter filtering

use of an algorithm to aid in detecting crystal aging and to qualify
clocking information

Digital trunking requires synchronized clocking so that a shift in one clock
source results in an equivalent shift in all parts of the network. In the CS
1000 system, synchronization is accomplished with an NTAK20 clock
controller daughterboard in each Media Gateway that contains a digital
trunk card.

The NTAK20 clock controller daughterboard mounts directly on the following
cards:

NTAK09 1.5Mb DTI/PRI

NTBK50 2.0 Mb PRI

NTRB21 DTI/PRI/DCH TMDI

NT6D70 SILC

NT6D71 UILC

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008