Table 42 qsdi paddle board address switch settings – Nortel Networks Circuit Card 311 User Manual

Page 102

Advertising
background image

102

Option settings

Address

Switch SW15 or SW16 and logic on the card always address the four
UARTs using a pair of addresses: 0 and 1, 2 and 3 through 14 and 15. The
configurations for both switches are shown in

Table 42 "QSDI paddle board

address switch settings" (page 102)

. To avoid system problems, switches

SW15 and SW16 must not be configured identically.

Table 42
QSDI paddle board address switch settings

SW15

Port 1

Port 2

Switch settings

SW16

Port 3

Port 4

1*

2

+

3

4

5

6

7

8

0

1

E

X

off

off

off

off

off

off

2

3

E

X

off

off

off

off

off

on

4

5

E

X

off

off

off

off

on

off

6

7

E

X

off

off

off

off

on

on

8

9

E

X

off

off

off

on

off

off

10

11

E

X

off

off

off

on

off

on

12

13

E

X

off

off

off

on

on

off

Device

pair

addresses

14

15

E

X

off

off

off

on

on

on

* To enable ports 1 and 2, set SW15 position 1 to ON. To enable ports 3 and 4, set SW16 position 1
to ON.

+

For each X, the setting for this switch makes no difference, because it is not used.

DTE/DCE mode

Each serial port can be configured to connect to a terminal (DTE equipment)
or a modem (DCE equipment). Instructions for configuring the DTE/DCE
switches SW2, SW3, SW4, SW5, SW6, SW7, SW8, and SW9 are shown in

Table 43 "QSDI paddle board DTE/DCE mode switch settings" (page 103)

.

Example: Port 1 is changed from DTE to DCE by reversing every switch
position on SW3 and SW2; that is, switches that were off for DTE are turned
on for DCE, and switches that were on for DTE are turned off for DCE.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.