Tone and digit switch cards, Procedure 11 testing tone and digit switch cards – Nortel Networks Circuit Card 311 User Manual

Page 79

Advertising
background image

Tone and digit switch cards

79

****

5

Test an automatically identified outward dialing (AIOD) trunk card:

LD 41

AIOD l s c

loop, shelf, and card numbers

If the system response is other than OK, see Software Input/Output
Reference — Administration
(NN43001-611) to analyze the
messages.

6

End the session in LD 41:

****

—End—

Tone and digit switch cards

Procedure 11

Testing tone and digit switch cards

Step

Action

Use this procedure to test a tone and digit switch (TDS) card or to test the
TDS function of an NT8D17 Conference/TDS card.

1

Log into the system:

LOGI

(password)

2

Obtain a list of terminal numbers (TNs) for disabled TDS cards:

LD 34

STAD

3

If the TDS loop to be tested is disabled, enable it.

For an NT8D17 Conference/TDS card, enter:

ENLX loop

(the TDS/MFS loop is the even loop of the conference/TDS loop pair)

Note: The conference/TDS card is not enabled automatically
when it is inserted. You must enable the card with the command
ENLX. (This command is used in LD 34 and LD 46 to address
even loops and in LD 38 to address odd loops.) Enabling the
loops with the command ENLL does not enable the hardware
for the card.

For other than an NT8D17 Conference/TDS card, enter:

ENLL loop

4

Test the TDS loop:

TDS loop

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008