MFE signaling

367

Digit

Forward direction

DOD-Tx, DID-Rx

backward direction

DOD-Rx, DID-Tx

4

1380 Hz + 1740 Hz

1140 Hz + 780 Hz

5

1500 Hz + 1740 Hz

1020 Hz + 780 Hz

6

1620 Hz + 1740 Hz

900 Hz + 780 Hz

7

1380 Hz + 1860 Hz

1140 Hz + 660 Hz

8

1500 Hz + 1860 Hz

1020 Hz + 660 Hz

9

1620 Hz + 1860 Hz

900 Hz + 660 Hz

10

1740 Hz + 1860 Hz

780 Hz + 660 Hz

11

1380 Hz + 1980 Hz

1140 Hz + 540 Hz

12

1500 Hz + 1980 Hz

1020 Hz + 540 Hz

13

1620 Hz + 1980 Hz

900 Hz + 540 Hz

14

1740 Hz + 1980 Hz

780 Hz + 540 Hz

15

1860 Hz + 1980 Hz

660 Hz + 540 Hz

The exact meaning of each MFC signal number (1-15) within each level
can be programmed separately for each trunk route using MFC. This
programming can be done by the customer and allows users to suit the
needs of each MFC-equipped trunk route.

Each MFC-equipped trunk route is associated with a data block that
contains the MFC signal functions supported for that route.

MFE signaling

The NT5K21 XMFC/MFE card can be programmed for MFE signaling which
is used mainly in France. MFE is much the same as MFC except it has its
own set of forward and backward signals.

Table 164 "MFE Frequency values" (page 367)

lists the forward and

backward frequencies for MFE. The one backward signal for MFE is referred
to as the "control" frequency.

Table 164
MFE Frequency values

Digit

Forward direction

OG-Tx, IC-Rx

Backward direction

1

700 Hz + 900 Hz

1900 Hz

(Control Frequency)

2

700 Hz + 1100 Hz

3

900 Hz + 1100 Hz

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008